MODEL
NO. |
G-12-030C |
G-24-030C |
G-48-030C |
|
G-12-060C |
G-24-060C |
G-48-060C |
|
G-12-100C |
G-24-100C |
G-48-100C |
|
Output
power continuous |
300W |
600W |
1000W |
Output
power surge |
1000W |
1500W |
2000W |
AC
Output voltage |
100V
or 110V or 115V or 120V or 220V or 230V or 240V |
AC
inpout voltage |
AS ABOVE |
AS ABOVE |
AS ABOVE |
Regulation |
+/- 10% |
+/- 10% |
+/- 10% |
Output
wave form |
Modified Sine
Wave |
Modified Sine
Wave |
Modified Sine
Wave |
DC
input voltage |
10-15V(12V)
|
20-30V(24V) |
36-60V(48V)
|
Low
battery alarm |
DC10.5V+/-0.5V(12V)
|
DC21V+/-1V(24V) |
DC40V+/-1V(48V)
|
Low
battery shut-down |
DC10V+/-1V(12V)
|
DC20V+/-1V(24V) |
DC36V+/-1V(48V)
|
Frequency+/-1% |
60Hz
50Hz |
60Hz
50H24z |
60Hz
50Hz |
Efficiency |
90%
(12V) |
85%-90%
(24V) |
90%-95%(48V) |
No
load current draw |
<0.35A(12V) |
<0.18A(24V) |
<0.09A(48V) |
|
<0.95A(12V) |
<0.48A(24V) |
<0.24A(48V) |
|
<0.35A(12V) |
<0.68A(24V) |
<0.34A(48V) |
|
Charger
DC current draw |
3A |
3A |
3A |
Over
temperature protection |
55¢XC+/-5¢XC |
55¢XC+/-5¢XC |
55¢XC+/-5¢XC |
Cooling
fan |
YES |
YES |
YES |
Overload
protection |
YES |
YES |
YES |
Input
short circuit protection |
YES |
YES |
YES |
Dimensions
( LX WXH ) |
300 X 104 x
58 mm |
330 X 205 X
73 mm |
475 X 242 X
80 mm |
Net
weight |
1.9
KGS(approx.) |
2.8
KGS(approx.) |
4.65
KGS(approx.) |